temp_flash

Equipment Specs & Accessories

New!  EBB-460V Electric Bed Bug Heater - 2nd generation

Thermal Remediation EBB-460V Electric Bed Bug Heater 2nd GenerationThe newly redesigned EBB-460V (2nd Generation) Electric Bed Bug Heater offers enhanced performance - delivering more air for a faster temperature rise in the treated space.

Nearly 100 pounds lighter and 10 inches narrower than its predecessor, the EBB-460V produces 7000 watts at 2,400 cubic feet per minute (CFM) of heated air.  Also equipped with lockable, swivel casters, the updated unit allows applicators easier maneuverability through narrow doorways and landings.

The EBB-460V is standard in the trailer, expanded and house power equipment packages.  In a typical treatment, these heaters are placed within the space and recirculate the heated air for maximum efficiency.

Heating Capacity (Watts)
7000
Heating Capacity (BTU/hr)
24,880
Power Supply (volts/phase/hertz/amps)
460/3/60/20
Temperature Control
Digital Controller
NEMA Plug Style (Quan.)
L16-20P
Minimum Circuit Ampacity (Amps) 
15
Max. Overcurrent Protection (Amps) 
20
Operating Temperature Limits 
0-135°F 
Length x Width x Height (inches) 
24 x 18 x 50
Weight (lbs.) 
130

EBB-460V Electric bed bug Heater - 1st generation (UL Listed)

The EBB-460V Electric Bed Bug Heater (1st generation) is the original heater that came standard in the Expanded, Trailer, and Rental/House power equipment packages.   In a typical treatment, the heaters are placed within the space and recirculate the heated air for maximum efficiency.  These heaters are equipped with digital Watlow temperature controls to ensure temperature settings do not exceed 135F


Heating Capacity (Watts)
7000
Heating Capacity (BTU/hr)
24,880
Power Supply (volts/phase/hertz/amps)
460/3/60/20
Temperature Control
Digital Controller
NEMA Plug Style (Quan.)
L16-20P
Maximum Air Flow (CFM)
2,400
Motor Horsepower (Hp)
1.5
Total Power Consumption (Watts) 
8,100
Current Consumption (Amps) 
11.0     
Minimum Circuit Ampacity (Amps) 
15
Max. Overcurrent Protection (Amps) 
20
Operating Temperature Limits 
0-135°F 
Length x Width x Height (inches) 
29 x 28 x 48 
Weight (lbs.) 
225 

460V (4)-Heater Power Distribution Box

460V (4)-heater power distribution boxThe 4-heater power distribution box is brought inside the space to distribute power to the heaters.  A single main power cable runs from the generator to the distribution box, splitting the power for up to (4) EBB-460V heaters.

460V Main Power Cables

460V Main Power CablesMain power cables are used to connect the generator to the distribution box and can connect up to a distance of 800 feet.  These 460V / 50 Amp 6/4 main power cables come in 50’-75’ lengths.  (Recommended length due to cable weight.


460V Heater Patch Cables

460V Heater Patch CablesA heater patch cable connects the power from the distribution box to each EBB-460V heater and can connect to a distance up to 300 feet per heater.  These 460V / 20 amp cables come in sizes of 25 feet, 50 feet, and 75 feet.


460V Generator Whip

460V Generator WhipThe 460V 6/4 4-foot whip makes the connection to a rental generator or your own 460V / 3 ph power source.


460V 50 Amp All Weather Main Power Plugs

460V 50 Amp all weather main power plugsMale and Female ends for main power plug replacement.


460V 20 Amp Heater Patch Cable Plugs

460V 20 Amp Heater Patch Cable PlugsMale and Female ends for heater patch cable plug replacement.


EBB-115V Electric bed bug Heater

The EBB-115V Electric Bed Bug Heater is standard in the EBB-115V Hotel Package.  This unit can also be an excellent addition to enhance treatment times, using house power, in conjunction with the EBB-40KW Trailer Package.  This heater requires (6)-15 amp circuits for maximum BTU output.  (Not all 6 circuits needed to operate).

In a typical treatment, the heaters are placed within the space and recirculate the heated air for maximum efficiency.  These heaters are equipped with digital Watlow temperature controls to ensure temperature settings do not exceed 135F.



Heating Capacity (Watts)
7000
Heating Capacity (BTU/hr)
25,590
Power Supply (volts/phase/hertz/amps)
(6) 115/1/60/15 amp circuits
Temperature Control
Digital Controller
NEMA Plug Style (Quan.)
15-15P (6)
Maximum Air Flow (CFM)
2,400
Motor Horsepower (Hp)
1.0
Total Power Consumption (Watts) 
8,460
Current Consumption (Amps) 
75 (12.5) per circuit
Minimum Circuit Ampacity (Amps) 
15 per circuit
Max. Overcurrent Protection (Amps) 
20
Operating Temperature Limits 
0-135°F 
Length x Width x Height (inches) 
29 x 28 x 48 
Weight (lbs.) 
225 

120 Volt 12/3 High Visibility Extension Cords

120V 12/3 High Visibility Extension CordsThe 120 Volt 12/3 High Visibility Extension Cords are used as the main power cable to supply 120-volt power to the EBB-115V heater.  Available in 25’ and 50’ lengths. (Distance of 12/3 cord should not exceed 75’ per run).


220V Complete Power Distribution Box Kit

220V Complete Power Distribution Box KitThe 220V complete power distribution box kit can be used to tap into 220V power from a range or stove to provide the (6)-15 amp circuits of 115-volt power required for the EBB-115V heater.  The complete kit includes a distribution box, a 25’ main power cable, and 220V/50 amp dryer and range power cord adapters (both new and old style for a total of 4 adapters).


220V/50A Power Cord Adapter: Electric Dryer Plugs

220V/50A Power Cord Adapter Electric Dryer PlugsThese plugs allow you to tap into 220V house power from an electric dryer outlet to power your EBB-115V heater.  Includes both old and new style.


220V/50A Power Cord Adapter: Electric Range Plugs

220V/50A Power Cord Adapter Electric Range PlugsThese plugs allow you to tap into 220V house power from an electric range outlet to power your EBB-115V heater.  Includes both old and new style.


Wireless Temperature Monitoring System, Expandable

Thermal Remediation Wireless Temperature SystemReal-time, graphical temperature monitoring is an integral part of the Thermal Remediation heat treatment process of bringing heat, moving air, and monitoring temperatures.

The expandable, wireless temperature monitoring system includes a Netbook installed with proprietary temperature recording software, wireless signal devices for transmission up to 1,000 ft., and up to 100 wireless temperature sensors, all housed in a heavy duty, water and impact resistant case.

The system's data can be used to identify hot and cold spots in the treated area and regulate and control hot air distribution.  Data can be exported to assure customers that overheating did not occur and verify that target temperatures were achieved.

Wireless Temperature Monitoring System Spec Sheet

Fluke Infrared Handheld Thermometer

Fluke Infrafer Handheld ThermometerThe Fluke digital handheld infrared thermometer offers quick and reliable surface temperature readings. This unit can be used to check specific points of interest during the heat treatment.


Fluke Thermocouple Wire Thermometer

Fluke Thermocouple Wire ThermometerUse the Fluke thermocouple wire thermometer with J-Wire to monitor temperatures under carpet edges, wall voids, electrical outlets, and pipes, etc.


High Temperature Multifan

Thermal Remediation High Temperature MultifanThese custom designed, high temperature Multifans provide a high CFM with low amp draw and operate well in high temperatures. These fans are necessary to evenly distribute heated air throughout the space and target high infestation zones and contents like furniture and bedding. Available in 16” (2.6 amps, 3294 CFM) and 20” (3.7 amps, 4,765 CFM) sizes.


16” Multifan Adapter

16" Multifan AdapterThe 16" Multifan adapter attachment is used to direct heat at target areas. This adapter also accepts the 20” high temperature ducting. Includes 4 spring clamps per fan.


High Temperature Duct 20” Transition

High Temperature Duct 20" TransitionThe 20” high temperature fabric duct transition attaches to the 16” Multifan Adapter to accept all 20” high temperature ducting.


20” High Temperature Ducting

20" High Temperature DuctingHigh temperature fabric ducting can be attached to the 16” Multifan (using the adapter and transition) to manage and distribute heated air.  Made of fire-resistant materials, and available in various lengths.


AirWall

Thermal Remediation AirwallThermal Remediation Airwall Image        AirWalls can be used to isolate an area that will not be heated or partition off areas that will be heated in a progression. The 6’x10’ AirWall works great in stairwells and hallways, while the 10’ x 10’ AirWall can isolate areas like a kitchen, living room, family room, etc. Both sizes of AirWalls can be zipped together to build false walls or isolate larger spaces. The AirWall requires a 16” Multifan, adapter, 20” transition, and 20” high temperature ducting.


Wall Edge Duct

Wall Edge DuctThe wall edge duct is designed to focus heat on wall edges, baseboards, and carpet tacks, etc. The Wall Edge Duct requires a 16” Multifan, adapter, and 20” transition.  Made of fire-resistant materials.


EBB Protective Covers

EBB Heater Protective CoversProtective covers and used to protect heaters from rain, snow, and debris. This accessory also protects the units from scratching corners, edges, walls, doors, etc. during the move in process.


Sprinkler Head Covers

Sprinkler Head CoversSprinkler Head Covers protect fire suppression systems (sprinklers) and heat sensors from hot air. Constructed of highly insulated foam, the sprinkler head covers easily attach to a ceiling mounted sprinkler with a pull cord.


Door Sweep Seals

Door Sweep SealsDoor Sweep Seals are used to block air infiltration from under door jams. (Cut to size, and replace foam pipe insulation as necessary.)


Reflective Insulation

Reflective InsulationReflective Insulation is used to cover vents and air conditioners to prevent cool air infiltration during a heat treatment.  Insulation can also be used to isolate spaces and cover hard-to-heat cement, etc. Available in 48” x 25’ rolls.


Cable Clamps

Cable ClampCable clamps are used to properly gather and protect 115V extension cords or attach fan cords to top handle of fans for proper storage.


Stealthlite Rechargeable Flashlight

Stealthlite Rechargeable FlashlightIt’s very important to have a high quality flashlight for inspection during the treatment process. The Stealthlite is a rugged, indestructible, water-resistant flashlight with a light beam that can cut through water, smoke, fog, and rain. Rechargeable NiHM battery pack included.


Omega IPM Vacuum

Omega IPM VacuumPhysical removal of bed bugs with a Pest Vac is highly encouraged during the initial heat up process between temperatures of 100-120ºF when bed bugs emerge from their hiding places.

The IPM Vacuum comes standard with a HEPA cartridge filter, 9-foot clear safe hose, 19-inch rubber flexible gooseneck, a crack and crevice tool, two 20-inch extension wands, a 25-foot power cord, and a shoulder strap. All accessories fit neatly in the compartment under the lid. Weighs 11 lbs and runs on 115V .


Poly Tape

Poly tapeUse poly tape to seal windows, vents, and gaps to protect the space from air infiltration. This high quality tape will not leave a glue residue after being heated.